CT10x

In Stock

Smart Current Transformer

options

  • CT101 – up to 100A current monitoring
  • CT103 – up to 250A current monitoring

Features

  • Remote current monitoring
  • Threshold alarm reporting
  • Overrange event alerts
  • Cable temperature monitoring
  • Firmware over-the-air updates

Hardware

  • LoRaWAN wireless communication
  • Self-powered clamp design
  • USB Type-C configuration port
  • IP30 flame-retardant housing
  • -20°C to 70°C operation

Applications

Smart buildings, industrial machinery, energy management, preventive maintenance, electrical panels.

Sensor Types

  • RMS current sensing
  • NTC temperature sensor
  • LED status indicator
Request a Quote for a Product

Request a Quote for a Product

    Description

    CT10x Description

    Core Purpose

    The CT10x is a smart current transformer built for simple, non-invasive energy monitoring in indoor electrical systems. It measures RMS current and accumulated current data, then sends the readings remotely over LoRaWAN for centralized visibility. Its clamp-style detachable design allows fast installation on live conductors without shutting down equipment, which makes it practical for retrofits and active facilities.

    Connectivity and Communication

    This device uses LoRaWAN Class A communication to send current data, threshold alerts, and overrange alarms to standard gateways and network servers. This gives users dependable long-range reporting for smart buildings, machine monitoring, and other distributed electrical assets. USB Type-C is also available for local configuration, console access, firmware updates, and optional cable temperature sensor connection, making deployment and maintenance easier.

    Monitoring and Detection Capabilities

    The CT10x is designed for continuous current monitoring with a sampling frequency up to 3.3 kHz and reporting as fast as 1 second when real-time visibility is needed. In practice, this helps teams quickly spot unusual current behavior, overload conditions, or early machine faults before they become larger failures. Threshold alarms and overrange alarms further support fast response by notifying operators when electrical activity moves outside normal limits.

    Power and Environmental Suitability

    A major advantage of the CT10x is its self-powered operation through induced current, removing the need for batteries or extra wiring in most installations. When lower-current measurement or setup flexibility is needed, it can also be powered by 5V USB Type-C. Its IP30 housing, UL94 V0 flame-rated material, and operating range of -20°C to 70°C make it suitable for indoor industrial cabinets, building panels, and equipment rooms.

    Expansion and I/O Support

    The device includes practical expansion support through USB Type-C, which can connect an optional NTC temperature sensor for cable temperature measurement. This allows users to combine electrical load visibility with thermal awareness in the same monitoring point. The detachable CT101/CT103 design also improves installation flexibility in narrow or difficult panel spaces

    Product Variants

    The CT10x Smart Current Transformer is available in CT101 and CT103 versions, both featuring the same detachable clamp design, LoRaWAN connectivity, self-powered operation, and real-time RMS current monitoring for smart energy management.

    The CT101 is designed for electrical lines up to 100A, making it ideal for branch circuits, lighting panels, office power lines, and smaller machines. The CT103 supports higher-current lines up to 250A, making it better suited for HVAC systems, pumps, compressors, distribution boards, and larger industrial equipment.

    .

    Industry Applications

    CT10x Industrial Applications

    Smart Buildings

    The CT10x fits well in smart buildings for branch circuit monitoring, HVAC load observation, and equipment energy usage analysis. Its clamp installation and LoRaWAN connectivity make it easy to add monitoring without rewiring or disrupting building operations.

    Industrial Equipment Monitoring

    For machinery and production systems, the CT10x helps identify abnormal current patterns that often appear before equipment failure. Fast reporting and threshold alarms support predictive maintenance workflows and reduce unplanned downtime.

    Energy and Utilities

    In energy management projects, the device helps track current consumption trends across electrical feeders, distribution boards, and facility zones. The self-powered design is especially useful in retrofit energy audits where fast deployment matters.

    Facility Safety and Preventive Maintenance

    When paired with the optional cable temperature sensor, the CT10x can support safer electrical maintenance by watching both current behavior and cable heat conditions. This makes it useful for preventive inspections in switchboards, indoor panels, and electrical rooms.

    Specifications

    CT10x Specifications

    Electrical Measurement

    Parameter CT101 CT103
    Detection Parameter RMS Current RMS Current
    Sampling Frequency 3.3 kHz 3.3 kHz
    Working Frequency 50~60 Hz 50~60 Hz
    Rated Primary Current 100 Arms 250 Arms
    Rated Secondary Current 100 mArms 125 mArms
    Minimum Reporting Current * 6Arms (1min Interval)
    4Arms (10min Interval)
    12Arms (1min Interval)
    6Arms (10min Interval)
    Accuracy ±1 % (>5Arms), ±3 % (≤ 5Arms) ±1 % (>5Arms), ±3 % (≤ 5Arms)
    Resolution 1 mA 1 mA

    Temperature Sensor

    Parameter CT101 CT103
    Sensor type NTC NTC
    Measuring range -20°C ~ 100°C -20°C ~ 100°C
    Measuring accuracy ±1 % ±1 %

    Wireless Transmission

    Parameter CT101 CT103
    Protocol LoRaWAN® LoRaWAN®
    Antenna Connector 1 × 50 Ω SMA Connector (Center PIN: SMA Female) 1 × 50 Ω SMA Connector (Center PIN: SMA Female)
    Frequency CN470/IN865/RU864/EU868/US915/AU915/KR920/AS923-1&2&3&4 CN470/IN865/RU864/EU868/US915/AU915/KR920/AS923-1&2&3&4
    Tx Power 16 dBm (868 MHz)/22 dBm (915 MHz)/19 dBm (470 MHz) 16 dBm (868 MHz)/22 dBm (915 MHz)/19 dBm (470 MHz)
    Sensitivity -137dBm -137dBm
    Mode OTAA/ABP Class A OTAA/ABP Class A

    Others

    Parameter CT101 CT103
    Button 1 × Reboot Button 1 × Reboot Button
    LED Indicator 1 × Status/Alarm Indicator 1 × Status/Alarm Indicator
    Port 1 × USB Type-C for Power Supply, Configuration, Console or Cable Temperature Sensor Connection 1 × USB Type-C for Power Supply, Configuration, Console or Cable Temperature Sensor Connection
    Software Configuration USB Type-C or Downlink USB Type-C or Downlink
    Advanced Feature Threshold Alarm, Overrange Alarm, FUOTA Threshold Alarm, Overrange Alarm, FUOTA

    Physical Characteristics

    Parameter CT101 CT103
    Power Supply 1. Induced current power supply
    2. 5V by USB Type-C Port
    1. Induced current power supply
    2. 5V by USB Type-C Port
    Insulation Voltage 2.5kVac(r.m.s)(1mA/1min) 2.5kVac(r.m.s)(1mA/1min)
    Color/ Material Blue, PBT+PC (UL94 V0) Blue, PBT+PC (UL94 V0)
    Extension Cable Length 1m 1m
    Operating Temperature -20°C~70°C (-4°F~158°F) -20°C~70°C (-4°F~158°F)
    Storage Temperature -25°C~80°C (-13°F~176°F) -25°C~80°C (-13°F~176°F)
    Relative Humidity ≤ 95% (Non-condensing) ≤ 95% (Non-condensing)
    Ingress Protection IP30 IP30
    Dimensions 86.5 × 31 × 37.4 mm (3.4 × 1.22 × 1.47 in)
    Wire Hole: Ф 16 mm (Ф 0.63 in)
    Transceiver: 38 × 34.5 × 16 mm (1.5 × 1.36 × 0.63 in)
    CT Clamp: 68 × 86 × 41.8 mm (2.68 × 3.39 × 1.65 in)
    Wire Hole: Ф 16 mm (Ф 0.63 in)
    Weight 85.65 g Transceiver: 13.05 g
    CT Clamp: 276.75 g
    Installation Transceiver: Cable-tie Mounting (under integrated mode)
    CT Clamp: Suspended on the Testing Conductor
    Transceiver: Cable-tie Mounting (under integrated mode)
    CT Clamp: Suspended on the Testing Conductor
    Regulatory CE, FCC, UL508 CE, FCC, UL508
     
    Order Codes

    Order Codes

    SKU: CT101

    SKU: CT103

    Order by referencing this SKU — contact info@easynt.com

    Downloads

    Downloads and Datasheets

    Scroll To Top
    Close
    Close